Skip to content
ADO Beauty

Black Friday: 8% off the entire catalogue

From Friday 27 to Monday 30 November. Enter the code in your cart.

Shop the catalogue

Electrosurgical Units

Surtron Touch 200 electrosurgical unit

Touchscreen controls · monopolar, bipolar and vessel sealing · up to 200 W

€4,935.00−25%€3,701.25+ VAT 22%€4,515.53 incl. VAT

SKU 835.10100.T40

Sale restricted to healthcare and aesthetics professionals qualified to use it, subject to a declaration when ordering.

Description

The Surtron Touch 200 is operated from a large touchscreen: modes, power levels and programmes are selected by touching them, both during preparation and while the procedure is under way. The manufacturer presents it as a radiofrequency scalpel for microsurgery and precision surgery, in monopolar and bipolar mode.

To the series' cutting and coagulation currents (CUT, ENHANCED, BLEND, FORCED and SOFT COAG) it adds fulguration, bipolar cutting for transurethral resection (TUR), bipolar coagulation and vessel sealing up to 7 mm. With the Flash Timer function power is delivered for a set time, from 10 milliseconds to 30 seconds, with programmable repetition; if you prefer, you can work the traditional way, with the footswitch or button held down.

Working programmes are saved and recalled by name, the screen can have a light or dark background and the software is updated through the USB port. The Surtron safety checks remain: neutral plate and skin contact monitored continuously, self-diagnosis, activation from the handpiece or footswitch.

Features

  • Touchscreen display with the manufacturer's LeOS operating system
  • Monopolar: CUT, ENHANCED, BLEND, FORCED COAG, SOFT COAG, fulguration
  • Bipolar: pure cut, TUR cut, coagulation with automatic start and stop, vessel sealing up to 7 mm
  • Timed output from 10 ms to 30 s, repeatable
  • Storable working programmes
  • Monitoring of the plate/patient circuit (OC) and of contact with split plates
  • Self-diagnosis and monitoring of the power delivered
  • Activation from handpiece or footswitch; adjustable signal volume
  • Software update via USB

Technical data

  • Maximum CUT power 200 W at 300 Ω
  • Maximum ENHANCED power 150 W at 300 Ω
  • Maximum BLEND power 150 W at 300 Ω
  • Maximum FORCED COAG power 150 W at 200 Ω
  • Maximum SOFT COAG power 100 W at 200 Ω
  • Maximum FULGURATION power 100 W at 1,000 Ω
  • Maximum BIPOLAR PURE power 120 W at 50 Ω, BIPOLAR TUR 200 W at 50 Ω, BIPOLAR COAG 120 W at 50 Ω
  • Maximum VESSEL SEALING power 200 W at 50 Ω
  • Operating frequency 360 kHz, floating patient circuit (F)
  • Power supply 100–240 V, 50–60 Hz, power input 750 VA
  • Dimensions 370 × 145 × 300 mm, weight 5.8 kg
  • Class IIb medical device (Regulation (EU) 2017/745); Class I equipment with type CF applied part
  • Standards EN 60601-1, EN 60601-1-2, EN 60601-2-2

Included

  • Reusable handpiece with buttons
  • Kit of 10 assorted 5 cm electrodes
  • 3 blade electrodes 7 cm, 3 needle electrodes 7 cm, 3 ball electrodes 6 cm
  • Steel neutral plate and connecting cable
  • 2 single-use split neutral plates
  • Watertight footswitch
  • 5 m power cable
  • Holder for handpiece and electrodes

Warnings

  • Class IIb medical device, to be used by medical staff according to the manufacturer's instructions

This product is intended exclusively for healthcare and aesthetics professionals qualified to use it. By purchasing it you declare, under your own responsibility, that you are qualified to use it in your work, and you undertake to follow the manufacturer's instructions and warnings.